HIAC 8012
The HIAC 8012 liquid particle counter is ideal for testing dark viscous fluid without dilution. Fast and reproducible results with sample volumes as low as 3 mL and a 1% flow rate reproducibility gives industry leading consistency to your data.
Benefits of selecting the HIAC 8012 liquid particle counter:
Save time and stop diluting your samples
The HIAC 8012 can manage viscosities to 1800 cP, allowing your heaviest, thickest oil to be sampled without dilution
Use less sample to get liquid particle count results
Only 3mL of sample for a perfect HIAC result
Fast results increase laboratory throughput time
Sample and report particle counts in less than a minute with built-in menu-driven standards
HIAC accuracy, reliability and service
The HIAC 8012 is a workhorse! With unrivaled industry support and service the HIAC 8012 has over 25 years of field use, making it an industry standard and leader in reliability Supports ISO 4406, NAS 1638 and user-defined tests to MTD, ACFTD, and ISO 11171 particle counting standards
8000A Counter:
| Dimensions |
41 W x 31 D x 17 H cm (16” x 12” x 6.5”) |
| Weight |
5 kg (11 lbs) |
| Data |
Input/Output Printer, LCD display, RS-232C |
| Operating Environment |
7 to 52°C (45 to 126°F) 30 to 95% relative humidity, non-condensing |
| Power |
90 to 132 VAC ± 10%, 47 to 63 Hz 180 to 264 VAC ± 10%, 47 to 63 Hz |
SDS Syringe Driven Sampler:
| Dimensions |
28 w x 25.5 d x 57 h cm (11 x 10 x 22.5 inches) |
| Weight |
9.5 kg (21 lbs) |
| Sample Flow Rate |
20 mL/min |
| Maximum Sample Viscosity |
1800 centipoises |
| Operating Environment |
10 to 40°C (50 to 104°F) 0 to 80% relative humidity, non-condensing |
Sensors:
HRLD-400HC
|
Measurement Range (μm) |
2.0 min.-400 |
| Concentration Limit (<10% coincidence) |
18,000 particles per mL |
| Flow Rates (mL/min) |
10-50 |
| Pressure Limit |
69 bar (1000 psi) |
| Sample Temperature Limit |
65°C (150°F) |
| Calibration Options |
ASTM F658-87 (PSL spheres); ISO 4402 (ACFTD in oil); or ISO 11171 (MTD in oil). For pharmaceutical applications, sensor resolution can be factory tested in accordance with USP <788>. |
HRLD-100HC
|
Measurement Range (μm) |
1.2 to 100µ |
| Concentration Limit (<10% coincidence) |
18,000 particles per mL |
| Flow Rates (mL/min) |
10-50 |
| Pressure Limit |
69 bar (1000 psi) |
| Sample Temperature Limit |
65°C (150°F) |
| Calibration Options |
ASTM F658-87 (PSL spheres); ISO 4402 (ACFTD in oil); or ISO 11171 (MTD in oil). For pharmaceutical applications, sensor resolution can be factory tested in accordance with USP <788>. |
8000A:
| Part Number |
Description |
| 720-100-0032 |
Manual, 8000A |
| 510667 |
Power cord 220 vac |
| 400100 |
Power cord 115 vac |
| 460513 |
Printer paper |
| 500-100-0110 |
Fuse |
| 410-350-0400 |
Plug, Euroblock 4 pin |
| 410-350-0700 |
Plug, Euroblock 7 pin |
HRLD Sensor:
| Part Number |
Description |
| 720-100-0021 |
Manual, HRLD |
| 040219-01 |
Cleaning probe assy |
| 660-850-0001 |
Cleaning floss |
SDS:
| Part Number |
Description |
| 690-300-0002 |
Syringe, 10mL plastic coated |
| 401-059 |
Teflon tubing 1/4" 5' |
| 500-150-0050 |
Fuse |
| 808-010-200 |
Viton o-ring |
| 650-600-0003 |
Grease |
| 720-100-0042 |
Manual, SDS |
| 072500-01 |
Control cable |
| 400100 |
Power cord 115 vac |
| 510667 |
Power cord 220 vac |
Optional Accessories:
| Part Number |
Description |
| 460513 |
Printer Paper for model 8000A (price per roll) |
| 90240002 |
Sample Bottles, Standard 120 ml, case of 72 |
| 90240004 |
Sample Bottles, Clean 120 ml, case of 72 |
| 90240006 |
Sample Bottles, Certified Clean 120 ml, case of 72 |
| 185-003 |
Bottle cover, nylon film, pack of 100 |
| 200-600-0030 |
Software, PARS Version 4.0 Data collection, system control, and reporting software custom made for the model 8000A counter based systems. One license is required for each computer to be used with the software |
Common applications for the HIAC 8012 liquid particle counter include: