HIAC 9703+

HIAC 9703+ liquid particle counters are the leader in Pharmaceutical USP <788> quality control and research applications.  Designed for your liquid particle counting application needs, the HIAC 9703+ is highly configurable and easy to use.  PharmSpec software makes data management easy and assures security for 21 CFR Part 11 environments.  Easy.  Accurate.  HIAC.
HIAC 9703+ Liquid Particle Counter

Benefits of selecting the HIAC 9703+ liquid particle counter for USP <788> quality control and research applications for Life Sciences

Industry’s smallest samples
Perform a full suite of tests with just 1mL of product
Manages all your application needs
Handle a full range of sample volumes from1 mL to >1000 mL Pre-configured USP, EP, JP, and KP test routines
Eliminate uncertainty from data
Alarm notification when bubbles and/or sensor contamination has impacted particle counting results
Secure sample handling
Small vial holder ensures no expensive sample gets wasted
Easily configurable for maximum flexibility
Select a preferred flow rate and utilize interchangeable sensors from 0.5 to 600µm particle size detection
Avoid costly down time
On-site service significantly reduces down time - no shipping of your unit required. Automated notification when your unit is in need of routine service
Eliminate anxiety of data loss
Data loss recovery feature protects the results in the event of a power interruption or loss. Automatic database backup to a secure network location via PharmSpec
HIAC Particle Counting Instrument Validation Services
SOP assistance and IQ/OQ validation services Utilize HIAC expertise to get your system out of the box and commissioned

HIAC 9703+ Liquid Particle Counter

Weight 10.7 kg (23.6 lbs)
Dimensions 343mm W X 337mm D X 482mm H  (13.5 X 13.3 X 19.0 inches)
Operating Temperature 5 to 40°C (40 to 104°F) 0 to 80% relative humidity, non-condensing
Sample Temperature 5 to 40°C (40 to 104°F)
Power 100/230 VAC, 50/60 Hz, 67 W at 115/230 VAC
Viscosity Limit <50 cP
Sample Bottle Clearance 153 mm (6.02 inches)
Volume Accuracy > 95%
Flow Rate Accuracy > 95%
Sample Flow Rate 10 to 100 ml/min; Actual flow rate for the system is determined by the sensor’s flow rate with step-by-step instructions and Pass/Fail results.
Tare Volumes for Probes 0.091 ml for 81 L x 1.2 mm I.D (3.2 x 0.047 inches) 0.172 ml for 154 L x 1.2 mm I.D. (6.1 x 0.047 inches) 1.57 mi for 140 L x 6.35 mm I.D. (5.5 x 0.25 inches) – large bore

PharmSpec 3 Software - for use with the HIAC 9703+ Liquid Particle Counter

Processor Pentium® 1.0 GHz
Operating System Windows® XP with Service Pack 3 or later Windows Vista® with Service Pack 2 or later Windows 7 (32 bit)
Memory 512 MB of RAM
Hard Disk 2 GB of available hard-disk space
Drives CD drive, DVD drive, USB port or network connection is required for installation
Display Super VGA video adapter and monitor,1024 x 768 or higher resolution
Power Supply Uninterrupted power supply (UPS)
Removable Drive Removable drive for backing up data, such as a recordable CD or a network server that can back up the computer hard drive
Printer Color printer capable of printing at 300 dpi
COM Port USB port to connect to the particle counting system
Software Internet Explorer 6.0 or higher and Microsoft® Excel®, Word® or Adobe® Acrobat® (to access PharmSpec reports)
Name Type Language Date
HIAC 9703+ Brochure US PDF English 22 Nov 2011
HIAC HRLD Sensors Brochure US PDF English 22 Nov 2011
HIAC-Liquid-Particle-Counter-9703-Manual-English PDF English 22 Nov 2011
HIAC-Pharmspec-User-Guide PDF English 22 Nov 2011
Proven-Long-Life-Lasers-in-Optical-Particle-Counters PDF English 22 Nov 2011
HIAC 9703+ Brochure UK PDF English A4 22 Nov 2011
HIAC HRLD Sensors Brochure UK PDF English A4 22 Nov 2011

Included Accessories with the HIAC 9703+ Liquid Particle Counter

Part Number Description
90450001 Vial sampler probe, 0.063” O.D. X 5.88” long stainless steel
90620008 Vial sampler probe, 0.25” O.D. x 5.88” long Stainless steel
90630002 Nut, for securing vial sampler probes to the sensor
089208-01 Drain tube assembly
230-300-7052 Power Supply, +24 VDC @ 3A
VP623500 Universal EU Power Cord, AC, 6’ long,  230V
VP623501 US Power Cord, AC, 6' long, 115V
460-400-4799 USB Cable 2.0 Pro Series hi-speed
600-100-0003 Magnetic Stirrer Bar, Teflon coated
690-300-4808 Syringe, 10mL XLP style
808-010-200 O-ring Viton, 2-010 for use on sensor fittings, 2 each
680-000-0030 Allen Wrench, 1.5mm
DOC026.97.80097 9703+ User’s manual

Optional Accessories for the HIAC 9703+ Liquid Particle Counter

Part Number Description
2089006-01 Small vial sampling kit Includes: P/N 2089099-01, Vial clamp assembly P/N 90450004, Vial sampler probe 0.063” x 3” long P/N 690-300-4805, Syringe, 1 mL XLP style
2089099-01 Vial clamp assembly
90450004 Vial sampler probe 0.063” x 3” long
690-300-4805 Syringe, 1 mL XLP style
690-300-4809 Syringe, 25 mL XLP style
FACTORY_CAL_USP_PRE USP Factory calibration per USP <1788>
2089290-01 HRLD Sensor Holder assembly
2089291-01 MC-05 Sensor Holder assembly
2089179-01 Cable Assembly, HRLD to 9703 Plus

PharmSpec Software for use with the HIAC 9703+ liquid particle counter:

Easy-to-use test setup
  • USP, EP, JP, and KP compendial test recipes available at the push of a button
  • Design your own test recipe with PharmSpec procedure builder
Always safe and secure data
  • Secure database migration from old Windows operating systems to the new Windows 7 and beyond.
    • Configurable network backup and archiving
    • Fully 21 CFR Part 11 compliant
Software is pre-configured – no expertise required
  • USP<788>, USP<789>, EP, JP or KP compendial updates are free on an annual basis for licensed users
  • Intuitive set up for new users – alarms are available for invalid configuration and advanced notification of calibration due
Early detection of data anomalies
  • Stop chasing data anomalies with bubble detection and concentrated sensor alarming
  • Confirmation of all particle counting results; partial results are recorded for incomplete tests

Applications:

USP <788> Particulate Matter in Injections and Parenteral Infustions
  • HIAC 9703+ Liquid Particle Counting System
  • HIAC PharmSpec Liquid Particle Counting Software
  • HIAC HRLD Liquid Particle Counting Sensors
  • HIAC MC05 Liquid Particle Counting Sensor (sub-micron)
Regulatory Links:
  • USP <788>
  • USP <789>
  • USP <797>
USP <789> Particulate Matter in Ophthalmic Solutions:
  • HIAC 9703+ Liquid Particle Counting System
  • HIAC PharmSpec Liquid Particle Counting Software
  • HIAC HRLD Liquid Particle Counting Sensors
  • HIAC MC05 Liquid Particle Counting Sensor (sub-micron)
USP <797> Pharmaceutical Compounding - Sterile Preparations
  • HIAC 9703+ Liquid Particle Counting System
  • HIAC PharmSpec Liquid Particle Counting Software
  • HIAC HRLD Liquid Particle Counting Sensors
  • HIAC MC05 Liquid Particle Counting Sensor (sub-micron)
Liquid Particle Counting Release Test Standards:
  • USP <788> Particulate Matter in Injections and Parenteral Infusions
  • USP <789> Particulate Matter in Ophthalmic Solutions
  • USP <7897> Pharmaceutical Compounding - Sterile Preparations
  • Parenteral Drug Association
  • European Directorate for the Quality of Medicines & Healthcare