MET ONE A3432
The MET ONE A3432 manifold system is designed for operation with the MET ONE 3400 series portable air particle counters. The MET ONE A3432 air particle counter manifold system allows a single particle counter to sample up to 32 locations.
The benefits of using the MET ONE series A3432 air particle counting manifold system:
Industry leading technology with the MET ONE 3400 series portable air particle counters.
ISO 21501-4 reliability and accuracy Test Wizard for Easier Compliance, organize your clean room Flexible Communications – easy set up and data transfer Seamless Connectivity to Data Management Software
Economical clean room solution for facility monitoring:
Sample up to 32 locations per manifold ISO class 1 to 8
Eliminate false positives due to sample line contamination.
MET ONE A3432 air particle counting manifold system uniquely offers high flow purge through all sample lines
Random location sequencing
Sample high risk particle counter clean room locations more often
| Environment |
|
| Operating temperature |
12 to 41 ºC (55 to 105 ºF) |
| Operating humidity |
10% to 85% relative humidity, non-condensing |
| Storage temperature |
-40 to 71 ºC (40 to 160 ºF) |
| Storage humidity |
Up to 98% relative humidity, non-condensing |
| Maximum altitude |
2000 meters (6560 ft) |
| Operating location |
Indoor use only |
| Manifold |
|
| Number of ports |
32 |
| Sample tubing |
½" OD, ³/8" ID |
| Size |
(W x H x D) 305 x 318 x 406 mm (12" x 12.5" x 16") |
| Weight |
12.2 kg (26.9 lb) |
| Manifold controller |
|
| Power |
100-120 VAC, 750 mA max (T 1.0 A fuses) or 220-240 VAC, 375 mA max (T 0.5 A fuses) (specify voltage when ordering), 50/60 Hz |
| Size |
(W x H x D) 231 x 122 x 206 mm (9.1 x 4.8 x 8.1 in.) |
|
| Weight |
3.1 kg (6.7 lb) |
| Program cycle |
Up to 100 steps |
| Particle counter (additional) |
|
| Data storage |
400 samples, rotating buffer |
| Hold time |
15 seconds minimum when manifold is attached |
| 209E calculations |
On stored data |
| 3-digit display |
Displays the port number when the location light is on |
| Compliance |
|
| Certification |
UL, CSA and IEC certified by ETL, CE. Contact Hach for complete compliance details. |
Included Accessories
| Part Number |
Description |
| 2080359-01 |
Manifold |
| 2083034-01 |
Manifold controller |
| 400119 |
Controller cable |
| 400100 |
AC power adapter 115 VAC (depending on location) |
| 510667 |
AC power adapter 230 VAC (depending on location) |
| 2083006-01 |
Manifold cable |
| Variations available |
Vacuum pump |
| 2088927 |
Manifold cable adapter |
Optional Accessories
| Part Number |
Description |
| 960380 |
Tubing |
| 960011 |
Tubing, manifold to particle counter, ½" (optional) |
| 204684-01 |
Coupling shoe |
| 2082645-1 |
Isokinetic probe (optional) |
| 2082644-3 |
Wall mount bracket for isokinetic probe (optional) |